Hot water cylinder without a heat exchanger

Hot water cylinders, buffers and Tank in Tank

A vertical cylinder with Direct Glass enamel and no coil. From 200 to 1,000 litres.

Hot water cylinders, buffers and Tank in Tank
  • One heat exchangerA fixed coil, e.g. for the boiler.
  • Direct Glass enamelFired at 850 °C, 400 microns thick, to DIN 4753.
  • 50 mm insulationPolyurethane with a leatherette cover.
  • Thermometer0–120 °C thermometer and a sensor pocket.
  • Cleaning flangeFor inspecting and cleaning the tank.
  • Electric heating elementOptional, on request.

What makes the difference

  • Thermometer and cleaning flangeAt the front there is a 0–120 °C thermometer and a cleaning and inspection flange. The flange is used for the regular cleaning of scale and sediment from the tank.
  • Insulation with a leatherette coverThe 50 mm polyurethane insulation is covered by a leatherette jacket that closes with a zip.
  • Labelled connectionsEach port has a label with its use and size, e.g. "Hot water outlet 3/4″". The plumber sees at once what connects where.
  • Connection diagramThe manufacturer supplies the diagram for connecting to the boiler: heating flow and return to the coil, cold and hot water with a safety valve and an expansion vessel.
Technical data

Models

Cylinders without a heat exchanger · BL0

All have Direct Glass enamel, a magnesium anode, a cleaning flange and a 10 bar working pressure.

ModelTank capacityTank heightTank diameterDiameter without insulationRequired heightNet weightMaximum working pressureMaximum test pressureTank insulationTank steel
BL0200200lt1200 mm600 mm500 mm–70 kg10 bar15 bar50mm soft removable polyurethane3mm USD37,2 steel sheet
BL0500500lt1700 mm750 mm––141 kg10 bar15 bar55mm polyurethane, 52 kg/m³2.5mm USD37,2 steel sheet
BL0750750lt1800 mm1000 mm–2059.1 mm228 kg10 bar15 bar100mm soft removable polyurethane4mm USD37,2 steel sheet
BL010001000lt2000 mm–––243 kg10 bar–100mm soft removable polyurethane4mm USD37,2 steel sheet

Double-energy cylinders · BL1

All have Direct Glass enamel, a permanent coil, a magnesium anode and a 10 bar working pressure. Up to 500 litres the steel is 2.5 mm and the insulation 55 mm; on the 750 and 1,000 litre models, 4 mm and 100 mm.

ModelTank capacityHeat exchanger surfaceHeat exchanger volumeTank heightTank diameterRequired heightNet weightMaximum working pressureMaximum test pressureMaximum heat exchanger pressureTank insulationTank steel
BL1150150lt0.78 m²5lt1120 mm560 mm1252.2 mm64 kg10 bar15 bar25 bar55mm polyurethane, 52 kg/m³2.5mm USD37,2 steel sheet
BL1200200lt0.986 m²6.4lt1400 mm600 mm–77 kg10 bar15 bar25 bar55mm polyurethane, 52 kg/m³2.5mm USD37,2 steel sheet
BL1300300lt1.55 m²9.9lt1620 mm630 mm1738.2 mm102 kg10 bar15 bar25 bar55mm polyurethane, 52 kg/m³2.5mm USD37,2 steel sheet
BL1500500lt1.92 m²12.2lt1700 mm750 mm–141 kg10 bar15 bar25 bar55mm polyurethane, 52 kg/m³2.5mm USD37,2 steel sheet
BL1750750lt2.39 m²15.2lt1800 mm1000 mm2059.1 mm228 kg10 bar15 bar25 bar100mm soft removable polyurethane4mm USD37,2 steel sheet
BL110001000lt3.2 m²19.2lt2000 mm1000 mm2236.1 mm243 kg10 bar15 bar25 bar100mm soft removable polyurethane4mm USD37,2 steel sheet

Triple-energy cylinders · BL2

All have Direct Glass enamel, two permanent coils, a magnesium anode and a 10 bar working pressure. Up to 500 litres the steel is 2.5 mm and the insulation 55 mm; on the 750 and 1,000 litre models, 4 mm and 100 mm.

ModelTank capacityHeat exchanger surfaceHeat exchanger volumeTank heightTank diameterRequired heightNet weightMaximum working pressureMaximum test pressureMaximum heat exchanger pressureTank insulationTank steel
BL2150150lt0.53 / 0.78 m²8lt1120 mm560 mm1252.2 mm70 kg10 bar15 bar25 bar55mm polyurethane, 52 kg/m³2.5mm USD37,2 steel sheet
BL2200200lt0.78 / 0.99 m²–1400 mm600 mm–90 kg10 bar15 bar–55mm polyurethane, 52 kg/m³2.5mm USD37,2 steel sheet
BL2300300lt0.99 / 1.55 m²16.2lt1620 mm630 mm1738.18 mm130 kg10 bar15 bar25 bar55mm polyurethane, 52 kg/m³2.5mm USD37,2 steel sheet
BL2500500lt1.20 / 1.92 m²19.8lt1700 mm750 mm–155 kg10 bar15 bar25 bar55mm polyurethane, 52 kg/m³2.5mm USD37,2 steel sheet
BL2750750lt1.35 / 2.39 m²23.8lt1800 mm1000 mm2059.1 mm250 kg10 bar–25 bar100mm soft removable polyurethane4mm USD37,2 steel sheet
BL210001000lt1.97 / 3.02 m²31.7lt2000 mm1000 mm2236.1 mm285 kg10 bar15 bar25 bar100mm soft removable polyurethane4mm USD37,2 steel sheet

Double-energy cylinders · BLS

All have Direct Glass enamel, 50 mm insulation with a leatherette cover, a thermometer and a magnesium anode. Up to 500 litres the working pressure is 8 bar, from 1,000 litres 10 bar.

ModelTank capacityActual volumeHeat exchanger surfaceTank heightTank diameterNet weightMaximum working pressureMaximum test pressureTank insulationHydraulic connections
BLS-150150lt141lt0.93 m²1240 mm550 mm53.4 kg8 bar10 bar50mm rigid polyurethane, 44 kg/m³, leatherette coverDomestic water 3/4″ · coil 1″ · recirculation 3/4″
BLS-200200lt184lt1.03 m²1240 mm600 mm66 kg8 bar10 bar50mm rigid polyurethane, 44 kg/m³, leatherette coverDomestic water 3/4″ · coil 1″ · recirculation 3/4″
BLS-300300lt275lt1.58 m²1270 mm700 mm89 kg8 bar10 bar50mm rigid polyurethane, 44 kg/m³, leatherette coverDomestic water 1″ · coil 1 1/4″ · recirculation 1″
BLS-500500lt479lt1.97 m²2080 mm700 mm152.3 kg8 bar10 bar50mm rigid polyurethane, 44 kg/m³, leatherette coverDomestic water 1″ · coil 1 1/4″ · recirculation 1″
BLS-750750lt––2240 mm850 mm–––50mm soft polyurethane, leatherette coverDomestic water 1 1/4″ · coil 1 1/4″ · recirculation 1 1/4″
BLS-10001000lt941lt3.16 m²2210 mm950 mm279.8 kg10 bar13 bar50mm soft polyurethane, 15 kg/m³, leatherette coverDomestic water 1 1/4″ · coil 1 1/4″ · recirculation 1 1/4″
BLS-15001500lt–––––––50mm soft polyurethane, leatherette coverDomestic water 1 1/4″ · coil 1 1/4″ · recirculation 1 1/4″
BLS-20002000lt–––––––50mm soft polyurethane, leatherette coverDomestic water 1 1/4″ · coil 1 1/4″ · recirculation 1 1/4″

Triple-energy cylinders · BLS2

All have two heat exchangers, Direct Glass enamel, 50 mm insulation with a leatherette cover, a thermometer and a magnesium anode. Up to 500 litres the working pressure is 8 bar, from 1,000 litres 10 bar.

ModelTank capacityActual volumeHeat exchanger surfaceTank heightTank diameterNet weightMaximum working pressureMaximum test pressureTank insulationHydraulic connections
BLS2-150150lt138lttop 0.3 m² · bottom 0.6 m²1240 mm550 mm71.4 kg8 bar10 bar50mm rigid polyurethane, 44 kg/m³, leatherette coverDomestic water 3/4″ · coil 1″ · recirculation 3/4″
BLS2-200200lt183lttop 0.3 m² · bottom 0.6 m²1240 mm600 mm72.6 kg8 bar10 bar50mm rigid polyurethane, 44 kg/m³, leatherette coverDomestic water 3/4″ · coil 1″ · recirculation 3/4″
BLS2-300300lt276lttop 0.52 m² · bottom 0.65 m²1270 mm700 mm85.6 kg8 bar10 bar50mm rigid polyurethane, 44 kg/m³, leatherette coverDomestic water 1″ · coil 1 1/4″ · recirculation 1″
BLS2-500500lt468lttop 1.31 m² · bottom 1.97 m²2080 mm700 mm175 kg8 bar10 bar50mm rigid polyurethane, 44 kg/m³, leatherette coverDomestic water 1″ · coil 1 1/4″ · recirculation 1″
BLS2-10001000lt924lttop 1.58 m² · bottom 3.16 m²2250 mm950 mm310 kg10 bar13 bar50mm soft polyurethane, 15 kg/m³, leatherette coverDomestic water 1 1/4″ · coil 1 1/4″ · recirculation 1 1/4″
BLS2-15001500lt1428lttop 1.31 m² · bottom 2.63 m²2100 mm1200 mm389 kg10 bar13 bar50mm soft polyurethane, 15 kg/m³, leatherette coverDomestic water 1 1/4″ · coil 1 1/4″ · recirculation 1 1/4″
BLS2-20002000lt1865lttop 2.24 m² · bottom 4.75 m²2470 mm1200 mm530.4 kg10 bar13 bar50mm soft polyurethane, 15 kg/m³, leatherette coverDomestic water 1 1/4″ · coil 1 1/4″ · recirculation 1 1/4″

Horizontal cylinders · BLH0, BLH1, BLH2

All are installed horizontally, with 100 mm soft polyurethane insulation and a 10 bar working pressure.

ModelTank capacityTank lengthTank heightTank diameterNet weightMaximum working pressureMaximum test pressureMaximum heat exchanger pressureTank steelHeat exchanger surface
BLH010001000lt2150 mm1200 mm1000 mm310 kg10 bar15 bar25 barUSD37,2 steel sheet–
BLH015001500lt2150 mm1500 mm1300 mm532 kg10 bar15 bar25 barUSD37,2 steel sheet–
BLH020002000lt2150 mm1600 mm1400 mm610 kg10 bar15 bar25 barUSD37,2 steel sheet–
BLH030003000lt2700 mm1700 mm1500 mm1025 kg10 bar15 bar25 barUSD37,2 steel sheet–
BLH040004000lt2700 mm1900 mm1700 mm1043 kg10 bar15 bar25 barUSD37,2 steel sheet–
BLH050005000lt2700 mm2000 mm1800 mm1267 kg10 bar15 bar25 barUSD37,2 steel sheet–
BLH070007000lt3280 mm2200 mm2000 mm1680 kg10 bar15 bar25 barUSD37,2 steel sheet–
BLH090009000lt3400 mm2400 mm2200 mm2090 kg10 bar15 bar25 barUSD37,2 steel sheet–
BLH110001000lt2150 mm1200 mm1000 mm350 kg10 bar15 bar25 barUSD37,2 steel sheet3.2 m²
BLH115001500lt2150 mm1500 mm1300 mm572 kg10 bar15 bar25 barUSD37,2 steel sheet3.2 m²
BLH120002000lt2150 mm1600 mm1400 mm650 kg10 bar15 bar25 barUSD37,2 steel sheet3.2 m²
BLH130003000lt2700 mm1700 mm1500 mm1065 kg10 bar15 bar25 barUSD37,2 steel sheet5.4 m²
BLH140004000lt2700 mm1900 mm1700 mm1083 kg10 bar15 bar25 barUSD37,2 steel sheet5.4 m²
BLH150005000lt2700 mm2000 mm1800 mm1307 kg10 bar15 bar25 barUSD37,2 steel sheet5.4 m²
BLH170007000lt3280 mm2200 mm2000 mm1720 kg10 bar15 bar25 barUSD37,2 steel sheet5.4 m²
BLH190009000lt3400 mm2400 mm2200 mm2130 kg10 bar15 bar25 barUSD37,2 steel sheet5.4 m²
BLH210001000lt2150 mm1200 mm1000 mm390 kg10 bar15 bar25 barUSD37,2 steel sheet2 × 3.2 m²
BLH215001500lt2150 mm1500 mm1300 mm610 kg10 bar15 bar25 barUSD37,2 steel sheet2 × 3.2 m²
BLH220002000lt2150 mm1600 mm1400 mm690 kg10 bar15 bar25 barUSD37,2 steel sheet2 × 3.2 m²
BLH230003000lt2700 mm1700 mm1500 mm1105 kg10 bar15 bar25 barUSD37,2 steel sheet2 × 5.4 m²
BLH240004000lt2700 mm1900 mm1700 mm1123 kg10 bar15 bar25 barUSD37,2 steel sheet2 × 5.4 m²
BLH250005000lt2700 mm2000 mm1800 mm1347 kg–15 bar25 barUSD37,2 steel sheet2 × 5.4 m²
BLH270007000lt3280 mm2200 mm2000 mm1760 kg10 bar15 bar25 barUSD37,2 steel sheet2 × 5.4 m²
BLH290009000lt3400 mm–2200 mm2170 kg10 bar15 bar25 barUSD37,2 steel sheet2 × 5.4 m²

Buffer tanks · BUF0

All have soft 52 kg/m³ insulation with a PVC cover and a magnesium anode.

ModelTank capacityTank heightTank diameterDiameter without insulationRequired heightNet weightMaximum working pressureMaximum test pressureTank insulationTank steel
BUF0150150lt1120 mm560 mm450 mm1252.19 mm42 kg4 bar8 bar60mm soft polyurethane and cover, removable, 52 kg/m³2mm USD37,2 steel sheet
BUF0200200lt1400 mm600 mm480 mm–55 kg4 bar8 bar60mm soft polyurethane and cover, removable, 52 kg/m³2.5mm USD37,2 steel sheet
BUF0300300lt1620 mm630 mm520 mm1738.2 mm68 kg–8 bar60mm soft polyurethane and cover, removable, 52 kg/m³2.5mm USD37,2 steel sheet
BUF0500500lt1700 mm840 mm640 mm–77 kg4 bar8 bar100mm soft polyurethane and cover, removable, 52 kg/m³2.5mm USD37,2 steel sheet
BUF0750750lt1800 mm1000 mm800 mm2059.1 mm118 kg4 bar8 bar100mm soft polyurethane and cover, removable, 52 kg/m³4mm USD37,2 steel sheet
BUF010001000lt2000 mm1000 mm800 mm2236.1 mm139 kg4 bar8 bar100mm soft polyurethane and cover, removable, 52 kg/m³3mm USD37,2 steel sheet
BUF015001500lt2000 mm1300 mm1100 mm2385.4 mm267 kg4 bar8 bar100mm soft polyurethane and cover, removable, 52 kg/m³4mm USD37,2 steel sheet
BUF020002000lt2000 mm1400 mm1200 mm2441.3 mm302 kg4 bar8 bar100mm soft polyurethane and cover, removable, 52 kg/m³4mm USD37,2 steel sheet
BUF030003000lt2500 mm1500 mm1300 mm2915.4 mm–4 bar10 bar100mm soft polyurethane and cover, removable, 52 kg/m³6mm USD37,2 steel sheet
BUF040004000lt2650 mm1700 mm1500 mm3148.4 mm–4 bar10 bar100mm soft polyurethane and cover, removable, 52 kg/m³6mm USD37,2 steel sheet
BUF050005000lt2750 mm1800 mm1600 mm3286.7 mm–4 bar10 bar100mm soft polyurethane and cover, removable, 52 kg/m³6mm USD37,2 steel sheet
BUF070007000lt3200 mm2000 mm1800 mm3773.6 mm–4 bar8 bar100mm soft polyurethane and cover, removable, 52 kg/m³6mm USD37,2 steel sheet
BUF090009000lt–––––4 bar8 bar100mm soft polyurethane and cover, removable, 52 kg/m³7mm USD37,2 steel sheet

Buffer tanks with a heat exchanger · BUF1

All have soft 52 kg/m³ insulation with a PVC cover and a magnesium anode.

ModelTank capacityHeat exchanger surfaceTank heightTank diameterDiameter without insulationRequired heightNet weightMaximum working pressureMaximum test pressureMaximum heat exchanger pressureMaximum heat exchanger temperatureTank insulationTank steel
BUF1150150lt0.79 m²1120 mm560 mm450 mm1252.19 mm53.7 kg4 bar8 bar16 bar160 °C60mm soft polyurethane and cover, removable, 52 kg/m³2mm USD37,2 steel sheet
BUF1200200lt1 m²1400 mm600 mm480 mm–72 kg4 bar8 bar16 bar160 °C60mm soft polyurethane and cover, removable, 52 kg/m³2.5mm USD37,2 steel sheet
BUF1300300lt1.8 m²1620 mm630 mm520 mm1738.18 mm97 kg4 bar8 bar16 bar160 °C60mm soft polyurethane and cover, removable, 52 kg/m³2.5mm USD37,2 steel sheet
BUF1500500lt2.2 m²1700 mm840 mm640 mm–117.85 kg4 bar8 bar–160 °C100mm soft polyurethane and cover, removable, 52 kg/m³2.5mm USD37,2 steel sheet
BUF1750750lt2.7 m²1800 mm1000 mm800 mm2059.1 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³3mm USD37,2 steel sheet
BUF110001000lt3.0 m²2000 mm1000 mm800 mm2236.1 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³3mm USD37,2 steel sheet
BUF115001500lt3.7 m²2000 mm1300 mm1100 mm2385.3 mm––8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³4mm USD37,2 steel sheet
BUF120002000lt4.0 m²2000 mm1400 mm1200 mm2441.3 mm–4 bar–16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³4mm USD37,2 steel sheet
BUF130003000lt3.2 m²2500 mm1500 mm1300 mm2915.4 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³5mm USD37,2 steel sheet
BUF140004000lt5.4 m²2650 mm1700 mm1500 mm3148.4 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³5mm USD37,2 steel sheet
BUF150005000lt5.4 m²2750 mm1800 mm1600 mm3286.7 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³5mm USD37,2 steel sheet
BUF170007000lt7.8 m²3200 mm2000 mm1800 mm3773.6 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³6mm USD37,2 steel sheet
BUF190009000lt7.8 m²3300 mm2200 mm2000 mm3966.1 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³7mm USD37,2 steel sheet

Buffer tanks with two heat exchangers · BUF2

All have soft 52 kg/m³ insulation with a PVC cover and a magnesium anode.

ModelTank capacityHeat exchanger surfaceTank heightTank diameterDiameter without insulationRequired heightNet weightMaximum working pressureMaximum test pressureMaximum heat exchanger pressureMaximum heat exchanger temperatureTank insulationTank steel
BUF2150150lt0.48 / 0.79 m²1120 mm560 mm450 mm1252.2 mm62.6 kg4 bar8 bar16 bar160 °C60mm soft polyurethane and cover, removable, 52 kg/m³2mm USD37,2 steel sheet
BUF2200200lt0.79 / 1 m²1400 mm600 mm480 mm–86.7 kg4 bar8 bar16 bar160 °C60mm soft polyurethane and cover, removable, 52 kg/m³2.5mm USD37,2 steel sheet
BUF2300300lt1.8 / 1.8 m²1620 mm630 mm520 mm1738.2 mm111.9 kg4 bar8 bar16 bar160 °C60mm soft polyurethane and cover, removable, 52 kg/m³2.5mm USD37,2 steel sheet
BUF2500500lt2.2 / 2.2 m²1700 mm840 mm640 mm–155 kg4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³2.5mm USD37,2 steel sheet
BUF2750750lt2.7 / 2.7 m²1800 mm1000 mm800 mm2059.1 mm216 kg4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³3mm USD37,2 steel sheet
BUF210001000lt3.0 / 3.0 m²2000 mm1000 mm800 mm2236.1 mm261 kg4 bar8 bar–160 °C100mm soft polyurethane and cover, removable, 52 kg/m³3mm USD37,2 steel sheet
BUF215001500lt2.5 / 3.7 m²2000 mm1300 mm1100 mm2385.3 mm362.2 kg4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³4mm USD37,2 steel sheet
BUF220002000lt2.7 / 4.0 m²2000 mm1400 mm1200 mm2441.3 mm403.8 kg4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³4mm USD37,2 steel sheet
BUF230003000lt3.2 / 3.2 m²2500 mm1500 mm1300 mm2915.4 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³5mm USD37,2 steel sheet
BUF240004000lt5.4 / 5.4 m²2650 mm1700 mm1500 mm3148.4 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³5mm USD37,2 steel sheet
BUF250005000lt5.4 / 5.4 m²2750 mm1800 mm1600 mm3286.7 mm––8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³5mm USD37,2 steel sheet
BUF270007000lt7.8 / 7.8 m²3200 mm–1800 mm––4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³6mm USD37,2 steel sheet
BUF290009000lt7.8 / 7.8 m²3300 mm2200 mm–3966.1 mm–4 bar8 bar16 bar160 °C100mm soft polyurethane and cover, removable, 52 kg/m³7mm USD37,2 steel sheet

Buffer tanks with a stainless steel heat exchanger · BUFi1

All have soft 52 kg/m³ insulation with a PVC cover and a magnesium anode.

ModelTank capacityTank heightTank diameterDiameter without insulationRequired heightNet weightMaximum working pressureMaximum test pressureTank insulation
BUFi1500500lt1720 mm840 mm640 mm–95.3 kg4 bar8 barsoft polyurethane and cover, removable
BUFi1750750lt1820 mm1000 mm800 mm2059.1 mm127.8 kg–8 barsoft polyurethane and cover, removable
BUFi110001000lt2020 mm1000 mm800 mm–143.6 kg4 bar8 barsoft polyurethane and cover, removable
BUFi115001500lt2020 mm1300 mm1100 mm–277.8 kg4 bar8 barsoft polyurethane and cover, removable
BUFi120002000lt2020 mm1400 mm1200 mm–302 kg4 bar8 barsoft polyurethane and cover, removable

Tank in Tank · Tit0, Tit1, Tit2

All have Direct Glass enamel on the hot water tank, 100 mm insulation and a magnesium anode.

ModelTank capacityTank heightTank diameterDiameter without insulationRequired heightNet weightTank insulationInner tank liningHeat exchanger surfaceMaximum heat exchanger pressureMaximum heat exchanger temperature
Tit0-500500lt1740 mm840 mm640 mm–125.5 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–––
Tit0-750750lt1840 mm1000 mm800 mm–163 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–––
Tit0-10001000lt2040 mm1000 mm800 mm–178.8 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–––
Tit0-15001500lt2040 mm1300 mm1100 mm–313 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–––
Tit0-20002000lt2040 mm1400 mm1200 mm2499 mm348.2 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–––
Tit1-500500lt1740 mm840 mm640 mm–158.85 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C2.2 m²16 bar160 °C
Tit1-750750lt1840 mm1000 mm800 mm–204.2 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C2.7 m²16 bar160 °C
Tit1-10001000lt2040 mm1000 mm800 mm–224.2 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C3.0 m²16 bar160 °C
Tit1-15001500lt2040 mm1300 mm1100 mm–370.1 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C3.7 m²16 bar160 °C
Tit1-20002000lt2040 mm–1200 mm–408.2 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C4.0 m²16 bar160 °C
Tit2-500500lt1740 mm840 mm640 mm–192.2 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–16 bar160 °C
Tit2-750750lt1840 mm1000 mm800 mm–245.4 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–16 bar160 °C
Tit2-10001000lt2040 mm1000 mm800 mm–270.8 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–16 bar160 °C
Tit2-15001500lt2040 mm1300 mm1100 mm–408.2 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–16 bar160 °C
Tit2-20002000lt2040 mm–1200 mm–449.8 kg100mm soft removable polyurethaneDirect Glass liquid enamel (Bayer), fired at 850 °C–16 bar160 °C

Manufacturer’s data. Data sheets (PDF) and certificates on request.

Questions

What does "double energy" mean?

That the water is heated in two ways: by the heat exchanger, connected for example to the boiler, and by an electric heating element, fitted on request. If you also want to connect solar collectors, you need a triple-energy cylinder with two heat exchangers.

Will it fit in my room?

The comparison shows the dimensions of each size.

Which size do I need?

It depends on how much hot water you use and on the heat source. The comparison also shows the heat exchanger surface of each size. Call us and we will work it out together.

What servicing does it need?

The magnesium anode is checked at least twice a year and replaced when it is used up. In suitable water it lasts about 2 years, but it may need replacing after 6 months. Cleaning is done through the flange, without chemicals.

What warranty does it have?

7 years. It requires installation following the manufacturer's instructions, water within drinking water limits and regular checks of the magnesium anode, which is a consumable and is not covered.

Prices and availability for distributors

Send us your company details and the models you are interested in.

Request prices